Peacekeeper Cable Barrier System
CRASH-RATED CABLE BARRIER SYSTEM SPECS and Technical Data
Specifications
Performance Ratings (ASTM F2656)
M30 (K4) – P1 & P2 Configurations
• 15,000 lb vehicle @ 30 mph
M50 (K12) – P1 & P2 Configurations
• 15,000 lb vehicle @ 50 mph
P1: ≤ 1 m penetration | P2: ≤ 3 m penetration
Engineered (SDOF) and fully Certified configurations available.
System Configuration
Post Spacing
• 20 ft standard spacing (P1)
• Up to 200 ft line post spacing (P2)
Cable Assembly
• Dual high-strength steel cables
• Closed spelter socket terminations
Post Construction
• Steel terminal and intermediate posts
• Stand-alone or integrated configurations
Foundations
• Reinforced concrete foundations
• 4,000 PSI minimum concrete
• Terminal and intermediate post foundations per engineered drawings
Compliance & Standards
• ASTM F2656 crash-rated
• DOS and DOD applicable ratings available
• Additional PU30–PU60 ratings available
Customization Options
• Custom post heights
• Project-specific spacing
• Integration with fencing systems
• Engineered submittal packages available
Explore other Bad Day Fabrications anti-ram barrier systems, including crash-rated solutions.
ASTM F2656 crash testing standards
Engineering Documentation
Cut Sheet (PDF)
Cable barrier system specs, crash ratings, operating options, and available features for the Peacekeeper Cable Barrier System.
General Arrangement Drawing – M30-P1 Crash Rated Layout (PDF)
Detailed GA drawing including installation footprint and dimensions.
General Arrangement Drawing – M30-P2 Crash Rated Layout (PDF)
Detailed GA drawing for the M30-P2 crash-rated barrier configuration.
General Arrangement Drawing – M50-P1 Crash Rated Layout (PDF)
Detailed GA drawing including installation footprint and dimensions.
General Arrangement Drawing – M50-P2 Crash Rated Layout (PDF)
Detailed GA drawing for the M50-P2 crash-rated barrier configuration.
Crash Tests
M50 (P1) Rating – 20 ft Configuration
• Close-up view (Video)
• Side view (Video)
• Oblique view (Video)
M50 (P2) Rating – 200 ft Configuration
• Close-up view (Video)
• West center stanchion performance (Video)
• East terminal stanchion performance (Video)