TECHNICAL RESOURCES.

Peacekeeper Cable Barrier System

CRASH-RATED CABLE BARRIER SYSTEM SPECS and Technical Data

Specifications

Performance Ratings (ASTM F2656)
M30 (K4) – P1 & P2 Configurations
• 15,000 lb vehicle @ 30 mph

M50 (K12) – P1 & P2 Configurations
• 15,000 lb vehicle @ 50 mph

P1: ≤ 1 m penetration | P2: ≤ 3 m penetration
Engineered (SDOF) and fully Certified configurations available.

System Configuration
Post Spacing
• 20 ft standard spacing (P1)
• Up to 200 ft line post spacing (P2)

Cable Assembly
• Dual high-strength steel cables
• Closed spelter socket terminations

Post Construction
• Steel terminal and intermediate posts
• Stand-alone or integrated configurations

Foundations
• Reinforced concrete foundations
• 4,000 PSI minimum concrete
• Terminal and intermediate post foundations per engineered drawings

Compliance & Standards
• ASTM F2656 crash-rated
• DOS and DOD applicable ratings available
• Additional PU30–PU60 ratings available

Customization Options
• Custom post heights
• Project-specific spacing
• Integration with fencing systems
• Engineered submittal packages available

Explore other Bad Day Fabrications anti-ram barrier systems, including crash-rated solutions.

ASTM F2656 crash testing standards

Engineering Documentation

Cut Sheet (PDF)
Cable barrier system specs, crash ratings, operating options, and available features for the Peacekeeper Cable Barrier System.

General Arrangement Drawing M30-P1 Crash Rated Layout (PDF)
Detailed GA drawing including installation footprint and dimensions.

General Arrangement Drawing M30-P2 Crash Rated Layout (PDF)
Detailed GA drawing for the M30-P2 crash-rated barrier configuration.

General Arrangement Drawing M50-P1 Crash Rated Layout (PDF)
Detailed GA drawing including installation footprint and dimensions.

General Arrangement Drawing M50-P2 Crash Rated Layout (PDF)
Detailed GA drawing for the M50-P2 crash-rated barrier configuration.


Crash Tests

M50 (P1) Rating – 20 ft Configuration
Close-up view (Video)
Side view (Video)
Oblique view (Video)

M50 (P2) Rating – 200 ft Configuration
Close-up view (Video)
West center stanchion performance (Video)
East terminal stanchion performance (Video)

Scroll to Top